Filter Results By:

Products

Applications

Manufacturers

Insulation Oil

measures the breakdown voltage of insulating oils.


Showing results: 31 - 45 of 78 items found.

  • *High Current Switches

    B-1002 - Ruetz Technologies GmbH

    Ross High Current Switches are available up to 36,000 amps continuous and over 1,700,000 amps 20µsec RC pulse, with voltage ratings of 6 volts to 400kV peak test. Standard Ross high current switches are built with 80 to 120psi air cylinder actuators. Air cylinder or motor operated for high contact force.  Arcing contacts optional for closing current. G-10 epoxy glass laminate is standard insulation on most models. G-7 silicone glass is used on models available for RF applications above 100kHz.  Most Ross high current switches are available with additional lengths of insulation, where the high voltage contacts need to be spaced at a greater distance from the actuator and control circuit.  Voltage withstand value is at least doubled and the interrupt capability is much greater when high current switches are immersed in insulating oil, fluid or SF6 gas.  For gas atmosphere, no modifications are necessary; however, oil or fluid immersion requires modification at a slight extra cost.

  • High Current Switches

    B-1002 - ROSS ENGINEERING CORPORATION

    Ross High Current Switches are available up to 36,000 amps continuous and over 1,700,000 amps 20µsec RC pulse, with voltage ratings of 6 volts to 400kV peak test. Standard Ross high current switches are built with 80 to 120psi air cylinder actuators. Air cylinder or motor operated for high contact force.  Arcing contacts optional for closing current. G-10 epoxy glass laminate is standard insulation on most models. G-7 silicone glass is used on models available for RF applications above 100kHz.  Most Ross high current switches are available with additional lengths of insulation, where the high voltage contacts need to be spaced at a greater distance from the actuator and control circuit.  Voltage withstand value is at least doubled and the interrupt capability is much greater when high current switches are immersed in insulating oil, fluid or SF6 gas.  For gas atmosphere, no modifications are necessary; however, oil or fluid immersion requires modification at a slight extra cost.

  • Wet-Mateable Connector, 10k V, 250 A

    Nautilus WM10-250 - Teledyne Marine ODI

    ​Trends in subsea oil & gas production are moving towards deeper water and longer step out distances. These trends drive demand for higher power equipment and higher power delivery and distribution capabilities subsea with high pressures and temperatures. Teledyne ODI'™s Nautilus WM10-250 is designed with the benefit of advanced material science testing and certification, and with insulation and redundant sealing systems for reliable performance in long-term harsh environments.

  • HV Rotary Switches

    B-1003 - ROSS ENGINEERING CORPORATION

    A key feature of our rotary switches is their simple mechanical design which results in conservative stress levels for trouble-free, long life use.  In addition, each rotary switch has a reinforced chassis design utilizing G-10 or G-11 fire retardant anti-tracking coated epoxy glass insulation.  G-7 silicone glass is used for special applications where RF or high temperatures are involved.  Heavy duty contacts, specifically designed to minimize corona in the Ross rotaries, are made of highly conductive yet weld resistant alloy with high contact closing force.  This high force gives our rotary switches high momentary current capability and a reputation for their ability to withstand high shock and vibration as well as other severe environmental conditions.  Ratings to 150kV, to 200A.  When immersed in insulating oil, fluid or gas, the voltage withstand value is at least doubled and the interrupt capability is much greater.  In a gas atmosphere, no modification is required. However, immersion in oil or fluid may require modification in some cases, at an extra cost (optional).  Each unit is either manually or electrically operated.  One SPDT contact is standard on most units.  The auxiliary contact is used as an interlock for protection against "Switching Hot".

  • All in one system 32KWH LiFePO4 Lithium Battery with AC Charger and 15KW Inverter for mobile vehicle application

    SPVLI-32KWH-INV15KW - Zhejiang Sandi Electric Co., Ltd

    Our All in one system 32KWH LiFePO4 Lithium Battery with AC Charger and 12-15KW 120/240V Inverter for mobile vehicle application ESS including LiFePO4 Lithium Battery with BMS, off grid pure sine wave inverter, AC/DC charger.All-in-one design, high integration and space saving installation;Using high-performance lithium iron phosphate cells, laser welding, good cell consistency, designed service life of more than 10 years; Charging and discharging are controlled separately, which is convenient and reliable to control charging and discharging. The discharge port will not be disconnected when over-charging, and the charging port will not be disconnected when over-discharging, the system has good stability;Master-slave mode, passive equalization, can manage the equalization resistance, can set the equalization start voltage difference, and monitor the equalization resistance temperature, more intelligent and safe, and reduce the impact of barrel effect on system energy storage;BMS adopts NXP(USA) automotive-grade high-performance chips, with strong anti-interference, good reliability and wide temperature range;CAN2.0 communication interface, has the advantages of strong real-time performance, long transmission distance, strong anti-electromagnetic interference ability;System parameters can be set through the host computer, such as fan start/stop temperature, charger maximum current setting, charge and discharge current correction, SOC correction, with insulation leakage detection function to prevent oil leakage and short circuit of the cell;Integrate Solar charge controller or AC charger optional, BMS communication control, more safe and reliable;Cell temperature management, can be automatically controlled with the air conditioner heater according to the cell condition to make the cell works at the most suitable temperature, and can be linked with the fire protection system as neededModel SPVLI-30KWH-INV12KWIsolation mode Low Frequency TransformerInverter PartBattery Input Rated Voltage (Vdc) 307VDC Voltage range (Vdc) 278-400VAC Output Rated output power 12KW Output waveform Pure Sine Wave Rated Voltage 120/240VAC Phases Split phase + N + PE Rated current (A) 50A(Phase Current) Frequency 60Hz Power Factor (PF) >0.95 Inverter Efficiency >92% Display LCD Overload Ability 150%, 35 secondsAC-DC Charger PartAC Input Voltage range(Vac) 180-240VacDC Output Rated voltage(Vdc) 330Vdc Rated current(A) 20ALithium Battery PartCell/Number 105AH/96PCSRated voltage 307VMax charge current 20AMax discharge current 100ACharge temperature range 0℃ ~ 50℃Discharge temperature range -20℃ ~ 50℃Cell charge end voltage 3.6VCell discharge end voltage 2.7VProtection Function Protection Input reverse polarity, under voltage, over voltage, output over-current, short circuit, overheating etc. Cooling method Fan-cooledDegree of protection IP20(indoor)Mechanical Dimension Depth* Width * Height 645x891x767mm Weight (Kg) 378Kg

  • Mini Degasifier

    AE865C - Amperis sl

    This lightweight cart mounted Mini-Degasser uses the latest high vacuum technology for filtering, dewatering and degassing of insulating and dielectric fluids. The equipment is ideal for processing oil in transformers and other similar locations.

  • Oil & Fuel Analysis

    BETA Laboratory

    BETA Laboratory is strongly positioned to supply superior analytical results foryour Insulating Oil, Lubricating Oil and Fuel Oil samples. As a provider to fossil,nuclear and alternative fuel generating facilities as well as industrial and commercialbusinesses, we deliver accurate results in accordance with ASTM Standards, driven bystringent ISO 9001 and nuclear quality control programs.

  • Oil Tan Delta Test Set

    Megger Group Ltd.

    The Oil Tan Delta (OTD) is a laboratory instrument, which measures the Tan Delta, Resistivity and Relative Permittivity of insulating liquids. These tests give a wider picture of the overall quality of the insulating oil, and will indicate if there is any contamination. Megger has developed features of the OTD to ensure that productivity levels within laboratories are maximised. OTD test sets are supplied with sixteen standard test sequences pre-installed, to support a set of international standards.

  • Resistivity Meter

    Eltel Industries

    Resistivity meterRSM-500 is used for measuring the volume resistivity of transformer oil and other electrical insulating liquids. • Auto ranged from 109 to 1015 ohm cm • Test voltages: internally generated +500V DC

  • Transformer Oil Furan Analyzer

    LC2010F - Chongqing Kailian Yongrun Industrial Co.,Ltd.

    It is designed to analyze furaldehyde and related furan compounds in transformer oil and other mineral insulating oils.

  • Insulating Transformer Oil Test Set

    Neutronics Manufacturing Co.

    NMC make Insulating BDV Oil Test Set are used to check the di-electric strength of the transformer oil.

  • Automatic Transformer Oil Test Set With Printer

    Neutronics Manufacturing Co.

    Oil Test is an equipment designed to test the dielectric strength of Insulating Oils as per relevant specifications vis. IS 6972. It is a useful equipment for Transformer / Switch Gear manufacturing units. Oil fettering agencies, repair shop and electrical maintenance departments.

  • Oil Withstand Voltage Tester

    TE 6080 - Wuhan Sangao Electrical Test Installations Limit Co.

    TE6080 Automatic insulating Oil Tester, in accordance with IEC156, realizes the full automatic determination of insulating oil dielectric strength, make the original tedious and dangerous work become safe and easy. The instrument adopts special software and hardware anti-interference measures to eliminate the competing products prone to crash phenomenon. The new design will reduce the volume to the 1 / 2 of original, easy to carry and operate on-site.

  • Transformer Oil BDV Tester (Single Cup)

    HTJY-80B / 288 - Wuhan Huatian Electric Power Automation Co., Ltd.

    The tester is designed to test the power strength of all kinds of insulating oil.

  • Insulating Oil Dielectric Loss Tester

    HTYJS-H / 275 - Wuhan Huatian Electric Power Automation Co., Ltd.

    Used for measuring dielectric loss and resistivity of insulating oil.